Rap 4.3 J322- S22 Element At Pyramid Timeout - GBC eWire Service Manual

Table of Contents

Advertisement

RAP 4.3
J322- S22 ELEMENT AT PYRAMID TIMEOUT
S22 Element at Pyramid time out is the maximum time to wait for the lead
edge of the element to reach the Element Detect at Pyramid sensor
1. Check if the element spool is loaded properly.
Element spool is loaded properly
Yes- Go to Step 2
No- Remove the element spool and reinsert it properly
2. Do GP 6.4 to check S22 Element Detect at Pyramid sensor
This clears the fault
Yes- Return to normal operation
No- Go to step 3
3. Check the condition of the Element belt (PL 5.8). Check for missing or
loose teeth in the belt
Element belt is in good condition
Yes- Go to Step 4
No- Replace the belt (REP 3.6)
4. Perform ADJ 1.5 to adjust the Element belt
This clears the fault
Yes- Return to normal operation
No- Go to Step 5
5. Do GP 6.5 to check M10 Element feed belt Motor.
This clears the fault
Yes- Return to normal operation
No- Go to step 6
6. Go GP 6.4 to check S25 Belt Home sensor
This clears the fault
Yes- Return to normal operation
No- Go to step 7
GBC eWire
7. Check the condition of the Element feed track assembly (PL 5.9)
Element feed track assembly is in good condition
Yes- Go to Step 8
No- Replace Element feed track assembly (REP 3.10)
8. Check the condition of the Element feed belt idler assembly (PL 5.9)
Element feed belt idler assembly is in good condition
Yes- Go to Step 9
No- Replace Element feed track assembly (REP 3.10)
9. Check the condition of the Element engagement guide (PL 5.9)
Element engagement guide is in good condition
Yes- Go to Step 10
No- Replace Element engagement guide (REP 3.13)
10. Check the condition of the Element belt idler (PL 5.9)
Element belt idler is in good condition
Yes- Go to Step 11
No- Replace Element belt idler (REP 3.11)
11. Check the condition of the Element sprocket nose sub-assembly (PL
5.9)
Element sprocket nose sub-assembly is in good condition
Yes- Go to Step 12
No- Replace Element sprocket nose sub-assembly (REP 3.12)
12. Do GP 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the
firmware for eWire.
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level
01-26-2018
2-31
RAPS