Installation Procedure
1. Position the new 24V Power Supply on the rear electrical panel.
2. Secure the new 24V Power Supply using M4 Screws (5).
3. Reconnect all connectors to the 24V power supply.
4. Do REP 1.5
Back Cover Replacement
5. Close the book drawer.
6. Connect the Power Cord.
7. Turn on power to the eWire.
GBC eWire
to install the Back Cover.

REP 11.5 RFI Filter Replacement

PARTS LIST ON PL 5.27
Use this procedure to remove and install the AC Filter Assembly.
Removal Procedure
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Remove the power cord
3. Note the location of the wires (3).
4. Remove the Wires (White/Black/Green) from the AC Filter.
5. Remove the M3 Screws (2) securing the AC Filter to the Electrical
Panel.
6. Remove the AC Filter from the Electrical Panel by pushing it forward
through the mounting plate.