Rep 3.15.10 Expanding T Spring Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

Installation Procedure
1. Secure the Expanding T flag to the new Expanding T Cam by
tightening the M3 Flat Head Screw.
2. Slide the new Expanding T Cam onto the Motor shaft.
3. Secure the new Cam by tightening the Set Screw.
4. Replace the Expanding T Top Cover.
5. Do REP 3.15
Element Transfer Module Replacement
Element Transfer Module.
6. Connect the Power Cord.
7. Power ON the eWire.
Repairs/Adjustments

REP 3.15.10 Expanding T Spring Replacement

PARTS LIST ON PL 5.13
Use this procedure to remove and install the Expanding T Spring. There
are 2 springs on each side of the module, for a total of 4.
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
to install the
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Remove the Expanding T top cover by removing the M3 Screws (4).
4. Remove the old spring by pulling the loop up and off the hook.
5. Repeat the procedure for the remaining springs.
01/26/2018