Rep 3.15.5 Horizontal Pushover Cam Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

Installation Procedure
1. Slide the rack under the mounting plate and align it to the mounting
holes on the module.
2. Secure the new Rack using the M3 screws.
3. Repeat the procedure for the remaining Rack Components if
necessary.
4. Replace the Element Transfer Top Cover.
5. Connect the Power Cord.
6. Power ON the eWire.
Repairs/Adjustments

REP 3.15.5 Horizontal Pushover Cam Replacement

PARTS LIST ON PL 5.13
Use this procedure to remove and install the Horizontal Pushover Cam.
There are 2 Horizontal Cams, which are the larger and outermost Cam
components.
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 3.15
Element Transfer Module Replacement
Element Transfer Module.
4. Note the orientation of the Hoizontal Cam.
5. Remove the retaining ring securing the Horizontal Cam to the shaft.
01/26/2018
4-86
to remove the
GBC eWire