Rep 2.18 Solenoid Replacement, Diverter Solenoid (L1) - GBC StreamWire Service Manual

Table of Contents

Advertisement

6. Remove the M4 Screws (2) and the Driver and Bracket Assembly.
7. Remove the M2.5 Screws (2) from the vertical connector on the
Stepper Driver. Remove the Stepper Driver by releasing it from the
plastic standoffs.
Installation Procedure
1. Place the new Stepper Driver onto the standoffs and snap it into
place. Note the orientation of the Driver PCB.
2. Tighten the M2.5 Screws (2) to secure the vertical portion of the
Driver.
3. Attach the Driver PCB Bracket into the Frame by securing the M4
Screws (2).
4. Set the Dip switches (6) on the new Motor Driver, using the correct
settings for the Stepper Motor in question. Refer to GP 6.5 for DIP
Switch settings.
5. Connect the Connectors (3).
6. Do REP 1.1
Top Cover Replacement
7. Connect the Power Cord.
8. Power ON the eWire.
Repairs/Adjustments
Screws (2)
to install the Top Cover.

REP 2.18 Solenoid Replacement, Diverter Solenoid (L1)

PARTS LIST ON PL 5.3
Use this procedure to remove and install the Diverter Solenoid Assembly.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Location of Diverter Solenoid shown below
4. Remove M3 Screws (2) connecting the Solenoid linkage to the
Diverter shaft.
07/23/2020
4-28
GBC StreamWire

Advertisement

Table of Contents
loading