Gp 6.4 Check Sensors - GBC eWire Service Manual

Table of Contents

Advertisement

GP 6.4
Check Sensors
Use the information in this section to locate the appropriate sensor(s) on
the eWire. Once you have located the sensor, follow
the function of the sensor. If the sensor does not operate as expected,
follow the troubleshooting steps located in this section to fix the faulty
sensor.
GP 6.4.1
Check S1-S5, S16, S43, S45
Locate sensors S1, S4, S5, and S16:
Raise the Top Cover.
The sensor windows are located on the Upper Bypass, oriented
toward the paper path.
Sensors S1, S4, S5, and S16 can be blocked manually by using
a piece of paper or other solid object.
Sensors S1, S4, S5 and S16 are on the Upper Bypass Panel (PL
5.2).
General Procedures and Information
GP 6.3.2
to verify
01/26/2018
Locate sensors S2 and S3:
Raise the Top Cover and the Lower Bypass panel.
If necessary, manually slide the closer assembly all the way
to the right of the machine.
Sensors S2 and S3 can be manually blocked by using a
piece of paper or other solid object.
Sensors S2 and S3 are located on the Deflector Module (PL 5.16).