5. Deflector Module

REP 5.1 Deflector Module Replacement

PARTS LIST ON PL 5.16
Use this procedure to remove and install the Deflector Module
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Raise the lid.
4. Disconnect the Deflector Cables by detaching the 3 cable headers.
Repairs/Adjustments
5. Remove the M4 Screws (2) from the front of the Deflector Module
6. Remove the M3 Screw and remove the cable cover plate from the
rear side of the Deflector