REP 3.14.3 Knife Anvil and Blade Replacement
PARTS LIST ON PL 5.11
Use this procedure to remove and install the Knife Anvil and Blade
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. NOTE: Handle the Knife Module carefully and keep fingers clear of
the knife blade edge.
4. Remove the M4 Screw and Nut securing the Knife Blade to the Knife
Module Arm. Set aside the Screw, Nut, and Washers.
Repairs/Adjustments
5. While securing the Knife Blade, press the Alignment Pins out of the
Knife Blade by pushing them through the opening.
6. Remove the Knife Blade.
01/26/2018
4-78
GBC eWire