Rap 4.9 J334- Feed Belt Jam - GBC eWire Service Manual

Table of Contents

Advertisement

6. Inspect Element transfer racks for obstructions. Inspect the
Expanding T Mechanism for loose parts or obstructions. (PL 5.13)
Element transfer mechanism is clear and in good condition
Yes- Go to Step 7;
No- Replace Element transfer racks (ARP 3.15.4)
7. Inspect Element transfer gears (PL 5.13)
Element transfer racks are in good condition
Yes- Go to Step 8;
No- Replace Element transfer gears (ARP 3.15.4)
8. Do GP 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the
firmware for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 9
9. Replace the Element transfer module (ARP 3.15)
This clears the fault
Yes- Return to normal operation;
No- Go to Step 10
10. Do ARP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level
GBC eWire
RAP 4.9
J334- FEED BELT JAM
Feed belt jam is reported when the Element home sensor does not
change state within the allowed time.
1. Check if the element spool is loaded properly.
Element spool is loaded properly
Yes- Go to Step 2;
No- Remove the element spool and reinsert it properly
2. Inspect the Element belt (PL 5.8). Check for missing teeth or any
other damages
Element belt is in good condition
Yes- Go to Step 3;
No- Replace the Element belt (REP 3.6)
3. Do GP 6.4 to check S25 Element belt home sensor
This clears the fault
Yes- Return to normal operation;
No- Go to step 4
4. Do ADJ 1.7 Element feed belt tension adjustment
This clears the fault
Yes- Return to normal operation;
No- Go to Step 5
5. Inspect Element feed belt idler for any damages or signs of wear (PL
5.8)
Element feed belt idler is in good condition
Yes- Go to Step 6;
No- Replace Element feed belt idler (REP 3.11)
6. Inspect Element belt idlers (2x) (PL 5.9)
Element belt idlers are in good condition
Yes- Go to Step 7;
No- Replace Element belt idler (REP 3.11)