RAP 5.21
J391- HOLDER ROTATE VERTICAL TIMEOUT
J391 is triggered if it takes longer than specified time for S34 Holder
Rotate vertical sensor to get covered, to indicate Holder rotate is in
vertical position.
1. Do GP 6.4 to check S34 Holder Rotate Vertical sensor
This clears the fault
Yes- Return to normal operation;
No- Go to Step 2
2. Do GP 6.5 to check M14 Holder Rotate motor
This clears the fault
Yes- Return to normal operation;
No- Go to step 3
3. Check the presence and tightness of the two socket head screws on
the holder rotate crack
Screws are present and sufficiently tight
Yes- Go to Step 4;
No- Tighten the screw and resume normal operation
4. Check for the presence and tightness of the fasteners shown in the
below image at the Holder rotate pivot
The fasteners are sufficiently tight
Yes- Go to Step 5;
No- Tighten the fasteners and resume normal operation
GBC eWire
5. Ensure the Front and Rear hinge brackets are positioned properly.
See below for the hardware
All the hardware is present
Yes- Go to Step 6;
No- Replace the missing components