Installation Procedure
1. Position the spring in the Closer and attach each end to the
corresponding mounting hole.
2. Repeat the process for the opposite Spring
3. Do REP 6.1
Closer Module Replacement
4. Connect the Power Cord.
5. Power ON the eWire.
Repairs/Adjustments
to install the Closer Module.

REP 6.7 Closer Release Solenoid Replacement

PARTS LIST ON PL 5.19
Use this procedure to remove and install the Closer Release Solenoid.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 6.1
Closer Module Replacement
4. Using an Allen wrench, remove the Shoulder Screws (3) securing the
Ejector Plate to the Closer Ejector Bracket.
5. Remove the Compression Spring from the Closer Ejector Plate.
6. Remove the Closer Ejector Plate from the Closer by pushing it
forward through the Closer Jaws.
7. Disconnect the Solenoid cable from the appropriate cable header.
8. Remove the Ejector Bracket from the Closer by loosening the M4
Screws (2).
9. Using an adjustable wrench, remove the Solenoid from the Ejector
Bracket.
Installation Procedure
1. Reverse the steps from the removal procedure.
2. Do REP 6.1
Closer Module Replacement
3. Connect the Power Cord.
4. Power ON the eWire.