Book Drawer Fault Codes; Rap 6.1 J442- Drawer Full Up Timeout; Rap 6.2 J443- Drawer Full Down Timeout - GBC eWire Service Manual

Table of Contents

Advertisement

6 BOOK DRAWER FAULT CODES

RAP 6.1
J442- DRAWER FULL UP TIMEOUT
J442 is triggered if it takes longer than specified time for the Book drawer
to reach its Full Up position (blocking S42 Book drawer Full up position)
1. Do GP 6.4 to check S42 Book Drawer Full Up sensor
This clears the fault
Yes- Return to normal operation;
No- Go to Step 2
2. Check the condition of the Book Drawer Lift Belt. Ensure that the belt
is not frayed or missing any teeth. Ensure that all screws are tight and
no parts are loose in the belt mechanism
Belt and Pulleys are in good condition
Yes- Go to Step 3
No- Replace the Book Drawer Belt or Pulley.
3. Inspect the Book Tray Drive Motor Belt (PL 5.24). Ensure that the belt
is not frayed or missing any teeth. Check the set screws on the Drive
Belt Pulleys to ensure all set screws are tight.
Belt and Pulleys are in good condition
Yes- Go to Step 4
No- Replace the Book Tray Drive Motor Belt
4. Do GP 6.5 to check M19 Book drawer elevation motor
This clears the fault
Yes- Resume normal operation;
No- Go to Step 5
5. Do 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the firmware
for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 8
6. Do REP 11.1 Main Control Board A Replacement
GBC eWire
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level
RAP 6.2
J443- DRAWER FULL DOWN TIMEOUT
J443 is triggered if it takes longer than the specified time for S43 a & b to
become unblocked when the book drawer is going down.
7. Do GP 6.4 to check S43 Book Drawer Full Down sensor
This clears the fault
Yes- Return to normal operation;
No- Go to Step 2
8. Check the condition of the Book Drawer Lift Belt. Ensure that the belt
is not frayed or missing any teeth. Ensure that all screws are tight and
no parts are loose in the belt mechanism
Belt and Pulleys are in good condition
Yes- Go to Step 3
No- Replace the Book Drawer Belt or Pulley.
9. Inspect the Book Tray Drive Motor Belt (PL 5.24). Ensure that the belt
is not frayed or missing any teeth. Check the set screws on the Drive
Belt Pulleys to ensure all set screws are tight.
Belt and Pulleys are in good condition
Yes- Go to Step 4
No- Replace the Book Tray Drive Motor Belt
10. Do GP 6.5 to check M19 Book drawer elevation motor
This clears the fault
Yes- Resume normal operation;
No- Go to Step 5
11. Do 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the firmware
for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 8
01-26-2018
2-77
RAPS

Advertisement

Table of Contents
loading