Rap 4.6 J325- S25 Feed Belt Home Timeout - GBC eWire Service Manual

Table of Contents

Advertisement

7. Replace the Element transfer module (REP 3.15)
This clears the fault
Yes- Return to normal operation
No- Escalate to second level
8. Do REP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 7
GBC eWire
RAP 4.6
J325- S25 FEED BELT HOME TIMEOUT
S25 Feed belt home time out is the maximum time to wait for the Element
belt home sensor to detect the belt tooth.
1. Do GP 6.4 to check S25 Element belt home sensor
This clears the fault
Yes- Return to normal operation
No- Go to step 2
2. Do GP 6.5 to check M10 Element feed belt motor
This clears the fault
Yes- Return to normal operation
No- Go to step 3
3. Inspect the Element belt (PL 5.8). Check for missing teeth or any
other damages
Element belt is in good condition
Yes- Go to Step 4
No- Replace the Element belt (REP 3.6)
4. Do ADJ 1.6 Element feed belt tension adjustment
This clears the fault
Yes- Return to normal operation;
No- Go to Step 5
5. Inspect Element feed belt idler for any damages or signs of wear (PL
5.9)
Element feed belt idler is in good condition
Yes- Go to Step 6
No- Replace Element feed belt idler (REP 3.11)
6. Inspect Element belt idlers (2x) (PL 5.9)
Element belt idlers are in good condition
Yes- Go to Step 7
No- Replace Element belt idler (REP 3.11)
01-26-2018
2-33