8. Inspect the closer jaw springs and ensure they are positioned
correctly.
The closer jaw springs are in good condition and positioned
correctly
Yes- Go to Step 9;
No- Replace closer jaw springs if necessary (REP 6.6)
9. Do 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the firmware
for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 10
GBC eWire
10. Replace Closer Module
This clears the fault
Yes- Return to normal operation;
No- Go to Step 11
11. Do REP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level
01-26-2018
2-65
RAPS