6. Ensure the linkages are not bent/damaged.
The linkages are not damaged
Yes- Go to Step 7
No- Replace the damaged components (REP 8.18)
7. Do 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the firmware
for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 8
8. Do REP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level
GBC eWire
RAP 5.22
J392- HOLDER STACK POSITION STEPS TIMEOUT
J392 is triggered when it takes longer than specified time for the holder to
go to stack position as it moves past S37 Holder Stack position sensor
Follow the Procedure in RAP 5.1
01-26-2018
2-74
RAPS