Rep 8.17 Holder Lock Sub-Assembly Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

REP 8.17 Holder Lock Sub-Assembly Replacement

PARTS LIST ON PL 5.22
Use this procedure to remove and install the Holder Lock Sub-Assembly
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Open the Lid and Lower Bypass.
4. Locate the Holder Lock Sub-Assembly.
5. Disconnect the Solenoid Cables at the header.
6. Remove the M4 Screw securing the Rear Hinge of the Holder Lock
Sub-Assembly to the Holder Frame. While supporting the Holder Lock
Sub-Assembly, remove the screw, washers, flange and stud.
7. Remove the M3 Screw securing the Upper Link of the Holder to the
Holder Lock Sub-Assembly Front Hinge.
GBC eWire
8. Remove the M4 Screw securing the Holder Frame to the Front Hinge
of the Holder Lock Sub-Assembly. While supporting the Holder Lock
Sub-Assembly, remove the screw, washers, flange and stud.
9. Remove the Holder Lock Sub-Assembly from the Holder.
Installation Procedure
1. Reverse the Steps found in the Removal Procedure
2. Connect the Power Cord
3. Turn power ON to eWire.
01/26/2018
4-161
Repairs/Adjustments

Advertisement

Table of Contents