GBC eWire Service Manual page 37

Table of Contents

Advertisement

Check that Cable 7716727 (See Section 7, page 7-3) is connected at
the AC Filter and the Power switch SW1 at the other end
Cable 7716727 (Black/White) is connected at both ends
Y
N
Connect Cable 7716727
9. Check that Cable 7716729 (See Section 7, page 7-3) is connected to
the Power Switch at one end and at the input terminals of the 24 VDC
Power Supply at the other end.
Cable 7716729 (Black/White) is connected at both ends
Y
N
Connect Cable 7716729
10. Check that Cable 7716726 (See Section 7, page 7-3) is connected to
the 24 VDC power supply and the Main Board A.
Cable 7716726 is connected.
Y
N
Connect Cable 7716726
11. Check for input voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) - at
the AC Filter terminals.
There is AC power at the AC Filter.
Y
N
Replace the AC power cord to the AC Filter.
12. Check for continuity at the AC Power Switch (PL 5.27).
There is continuity at the AC Power Switch.
Y
N
Replace AC Power Switch 7704376 (REP 11.6)
13. Check for voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) – on Cable
7716728 (See Section 7, page 7-3) at the AC Filter.
There is AC power on Cable 7716728 at the AC Filter.
Y
N
Replace AC FILTER (REP 11.5).
14. Check for voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) – on Cable
7716729 (See Section 7, page 7-3).
There is AC power on Cable 7716729.
Y
N
Replace Cable 7716729
GBC eWire
15. Check for output voltage – 24 VDC on Cable 7716726 at the 24 VDC
power supply.
There is DC power on Cable 7716726 at the Power Supply.
Y
N
Replace the 24 VDC power supply (REP 11.4)
Go to RAP 1.2 No DC Power
01-26-2018
2-13
RAPS

Advertisement