Rep 3.14.2 Knife Home Sensor Replacement S23 - GBC eWire Service Manual

Table of Contents

Advertisement

Installation Procedure
1. Align the new Emitter PCB on the mounting bracket and secure it
using the M2 Screws.
2. Connect the Emitter cable at the header and run the cable through
the wire clamps.
3. Attach the Upper Wire Cover using the M3 Screws (2).
4. Slide the new Receiver PCB into the Sensor Housing Assembly.
5. Run the Sensor cable through the opening and slide the Sensor
Housing Assembly into place. Secure the Sensor Housing Assembly
using the M2 Screw.
6. Install the Cable Conduit by tightening the M3 Screws (2).
7. Run the Receiver Cable through the cable clamps on the Cable
Conduit and connect it at the Cable Header.
8. Install the Lower Cable Cover using the M3 Screws (2).
9. Do REP 3.15
Knife Module Replacement
10. Connect the Power Cord.
11. Power ON the eWire.
Repairs/Adjustments
to install the Knife Module.

REP 3.14.2 Knife Home Sensor Replacement S23

PARTS LIST ON PL 5.11
Use this procedure to remove and install the Knife Home Sensor
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 3.15
Knife Module Replacement
4. Remove the Upper Cable Cover by removing the M3 Screws (2).
5. Remove the Sensor Bracket by removing the M3 Screws (3).
01/26/2018
4-76
to remove the Knife Module