Installation Procedure
1. Place the new Idler Roller with Bearing Housings into the Bushing
Forks.
2. Make sure the flat surface of the bushing aligns in the fork.
3. Rollers are non-directional so it does not matter which end goes in
each fork.
4. After the assembly is in place, gently pull the assembly outward and
release to ensure it moves freely in the fork.
5. Place the Extension Spring (2) over the Bearing Housings (2).
6. Place the hooks on the ends of the Extension Springs (2) on the
notches at the top of the Bushing Forks (2).
7. Do REP 5.1
Deflector Module Replacement
Module.
8. Connect the Power Cord.
9. Power ON the eWire.
Repairs/Adjustments
to install the Deflector

6. Closer Module

REP 6.1 Closer Module Replacement

PARTS LIST ON PL 5.19
Use this procedure to remove and install the Closer Module
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Raise the lid.
4. Remove the Cable Access Cover by removing the M3 Screws (2).
01/26/2018