RAP 5.14
J384- HOLDER AT CLOSER STEPS TIMEOUT
J384 is triggered when it takes longer than specified time for the holder to
get to S36 Holder at Closer sensor.
Follow the procedure in RAP 5.16
GBC eWire
RAP 5.15
J385- HOLDER DETECT AT GATE TIMEOUT
J385 is triggered when it takes longer than specified time for the Holder to
reach S39 Holder detect at Reverse Gate when the holder linear motor
M15 moves in the reverse direction.
1. Do GP 6.4 to check S39 Holder at Reverse gate sensor
This clears the fault
Yes- Return to normal operation;
No- Go to Step 2
2. Check the Condition of the Holder linear drive belt- Front and Rear
(PL 5.21)
The timing belt is in good condition. There are no missing teeth
and the belt is not frayed
Yes- Go to Step 3;
No- Replace the damaged timing belt (REP 8.11, 8.12) and resume
operation
3. Check the tension of the Holder linear drive belt tension- Front and
Rear (ADJ 1.6)
The tension of the timing belts is good
Yes- Go to Step 4;
No- Do to ADJ 1.6 to set the belt tension and resume operation
4. Visually check if the rollers of the Holder are centered in the cam
tracks.
The rollers are centered in the cam tracks
Yes- Go to Step 5;
No- Loosen the cam track assembly and bring the roller inside the
cam track. Resume operation
01-26-2018
2-66
RAPS