E) Add Elements; F) Close Door - GBC eWire Service Manual

Table of Contents

Advertisement

e) Add Elements

This message is displayed when the Element spool is removed from the
machine or when the Element spool is low on elements.
Use this procedure when the Add Elements message is displayed when
the Element spool containing elements is present in the machine.
1. Open the Element drawer door, remove the Element spool and
reinstall the spool.
This clears the fault.
Y
N
Go to Step 2.
Return to normal operation
2. Inspect if the Element spool barcode label is damaged, missing or not
centered on the hole
Bar code label is damaged or missing
Y
N
Go to Step 3.
Replace the spool with a new one and return to normal operation
3. Replace the element spool with another one. This is to troubleshoot
the error, so try any available size.
Replacing the Element spool clears the fault.
Y
N
Go to Step 3.
Return to normal operation
4. Do GP 6.4 to inspect S26 to S30, and S50
This clears the fault..
Y
N
Escalate to second level
Return to normal operation.
GBC eWire

f) Close Door

This message is displayed when the Door for the element feeder module
is left open or not properly closed.
1. Open the door, pull out the Element drawer and reinsert firmly.
This clears the fault
Y
N
Go to Step 2.
Return to normal operation
2. Insert an Interlock Cheater into the Book drawer interlock Switch.
Moving Parts, keep hands clear of nips and the belts when
the Interlock Cheater is inserted. See Section 0, page vii
for other languages.
3. Check if the Close Door message is displayed.
The Close Door message is displayed
N
Y
Do ADJ 1.7 Element Feeder door interlock switch adjustment.
Go to Step 4.
4. Do REP 1.5 to remove the Rear Cover and check if the Interlock
cable 7716714 is connected at J9 at the "A" Main control board.
Interlock cable is connected at J9
Y
N
Replace the cable and repeat Step 1.
5. Switch OFF machine and unplug power cord.
6. Remove the M4 screws that hold the Interlock Switch Bracket (PL
5.25) and inspect the connections at the Interlock Switch (see
REP 9.2 Interlock switch replacement for photos of the connections).
Interlock cable is connected at the Interlock switch.
Y
N
Make the connection and return to Normal operation
Go to step 7.
01-26-2018
2-7
WARNING
RAPS

Advertisement

Table of Contents
loading