Rep 9.8 Vacuum Fan Gasket Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

REP 9.8 Vacuum Fan Gasket Replacement

PARTS LIST ON PL 5.26
Use this procedure to remove and install the gasket at the Vacuum Fan to
Vacuum Module interface.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Turn off Power to the eWire.
2. Disconnect the Power Cord.
3. Raise the Transport Assembly and lift the Vacuum Stacker by pulling
on the Vacuum Stacker handle.
4. Using a flat tool, remove the Fan Gasket from the mating surface.
Repairs/Adjustments
Installation Procedure
1. Clean the mating surface carefully with alcohol and a clean cloth.
Remove any adhesive residue.
2. Align the new Gasket with the vacuum opening and press it down
firmly to adhere it to the metal surface.
3. Lower the Vacuum Stacker and close the lid.
4. Connect the Power Cord.
5. Turn on power to the eWire.
01/26/2018