REP 4.6 Idler Pulley Assembly Replacement

PARTS LIST ON PL 5.15
Use this procedure to remove and install the Vacuum Stacker Idler Pulley
Sub-Assembly
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 4.1
Vacuum Stacker Module Replacement
Vacuum Stacker.
4. Release the lock nut on the idler pulley tensioning screw and tighten
the screw into the Vacuum Stacker to loosen the belt tension on the
idler pulley.
GBC eWire
5. Lift the Idler Pulley Assembly up and off the tension adjustment
screws. If removing the Pulley Assembly is too difficult, tighten the
tension screws further by repeating the procedure in Step 4.
to remove the
6. Carefully slide the Idler Pulley Sub-Assembly away from the belt and
free of the machine. Take care to avoid damaging the Belt.
7. Repeat the procedure for the other side.