GBC eWire Service Manual page 51

Table of Contents

Advertisement

3. Do GP 6.4 to check sensor S1, S12, 13, 15, 6, 7, 8, 9, 10, 41, 2 and
3.
This clears the fault
Yes- Return to normal operation
4. Do GP 6.6 to inspect solenoids L2, L3, L4, and L7.
This clears the fault
Yes- Return to normal operation
5. Inspect rollers N8, N1, N2, N3, N4, N5 and N6- GP 6.14
This clears the fault
Yes- Return to normal operation
6. Inspect the gap between the deflector and ensure there are no
obstructions for smooth paper flow
There are no obstructions
Yes- Go to Step 7
No- Remove the obstruction, replace the Deflector module if
necessary REP 5.1.
7. Do GP 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the
firmware for eWire
This clears the fault
Yes- Return to normal operation
8. Do REP 5.1 to replace the Deflector module
This clears the fault
Yes- Return to normal operation
GBC eWire
No-
Go to Step 4
No-
Go to Step 5
No-
Go to Step 6
No- Go to Step 8
No-
Escalate to second level
01-26-2018
2-27
RAPS

Advertisement