10. While supporting the sub-assembly, remove the M5 Screws (2)
securing the front of the Knife Module and carefully remove the Knife
Module from the Element Feeder.
GBC eWire
Installation Procedure
1. Carefully slide the new Knife Module into position on the Element
Feeder. Line up the M5 screw holes with the appropriate threads on
the frame.
2. Secure the new Knife Module by tightening the M5 Screws (2 front, 1
back).
3. Connect the Knife cable at the header.
4. Replace the Element Feeder Back Cover by Securing the M4 Screws
(8). The bottom screws can be used as a support to help position the
cover.
5. Do GP 6.8 to replace the Element Spool.
6. Connect the Power Cord.
7. Power ON the eWire.