8. Using a screwdriver, remove the e-ring providing tension to the kick-
down retract spring. (Note: Spring retainer differs from picture below).
Loosen the kick-down retract spring.
9. Loosen and remove the M4 Screws (2) securing the kick-down
solenoid mounting bracket, and remove the bracket from the module.
Repairs/Adjustments
10. Use an adjustable wrench to loosen the nut securing the Solenoid to
the bracket.
11. Remove the Kick-Down Solenoid Assembly from the Vacuum
Stacker.