REP 5.8 Deflector Springs Replacement

PARTS LIST ON PL 5.16
Use this procedure to remove and install Extension Springs on the
Deflector. Note that the same procedure can be used for springs on each
side of the Deflector.
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 5.1
Deflector Module Replacement
Module.
4. Locate the appropriate Deflector Springs.
5. Remove the spring by unhooking it from the mounting holes on each
end. If necessary, loosen the M3 Screws (2) on the Spring Bracket.
GBC eWire
to remove the Deflector
01/26/2018
4-125
Installation Procedure
1. Attach one end of the Deflector Spring to the hole on the Spring
Bracket and attach the other end to the hole on the Kickdown
Linkage.
2. Secure the Screws on the Spring Bracket.
3. Do REP 5.1
Deflector Module Replacement
Module.
4. Connect the Power Cord.
5. Power ON the eWire.
to Install the Deflector