Rap 4.20 J369- Pushover Rev Encoder Timeout; Bind Jam Codes; Rap 5.1 J370- Holder At S37 Timeout - GBC eWire Service Manual

Table of Contents

Advertisement

RAP 4.20
J369- PUSHOVER REV ENCODER TIMEOUT
J368 is triggered if it takes longer than specified time to count the encoder
steps needed for the Pushover to go in the reverse direction.
Follow the procedure in RAP 4.17
GBC eWire

5 BIND JAM CODES

RAP 5.1
J370- HOLDER AT S37 TIMEOUT
J370 is triggered if it takes longer than specified time for the Holder to
reach S37. The holder then moves forward a set number of motor steps
for Stacking position
1. J370 may be triggered by an oversized book preventing the holder
from moving. Confirm that the book being run does not exceed listed
in the Book Quality Section of this manual.
Book was oversized
Yes- Return to normal operation;
No- Go to Step 2
2. Do GP 6.4 to check S37 Holder Stack position sensor
This clears the fault
Yes- Return to normal operation;
No- Go to Step 3
3. Check the Condition of the Holder linear drive belt- Front and Rear
(PL 5.21)
The timing belt is in good condition. There are no missing teeth
and the belt is not frayed
Yes- Go to Step 4;
No- Replace the damaged timing belt (ARP 2.8, 2.9) and resume
operation
4. Check the tension of the Holder linear drive belt tension- Front and
Rear (ADJ 1.6)
The tension of the timing belts is good
Yes- Go to Step 5
No- Do to ADJ 1.6 to set the belt tension and resume operation
01-26-2018
2-45
RAPS