GP 6.3.16
ELEM XFER POS
The Element Transfer Position setting will allow the operator to change
the position of the element on the Element Feeder Belt when it is
transferred to the holder.
Using the procedure described in
Use the up and down arrows to scroll down to the ELEM XFER POS
ELEM XFER POS
The below screen will appear
ELEM XFER POS
0
0 is the default setting. The Feed Belt Home value can be adjusted on a
range of -128 to +127. When the desired value has been selected,
press ENTER to return to the service menu.
Select EXIT and press ENTER to return to the top level menu
GP 6.3.17
ROTATE DELAY Setting
The Rotate Delay setting will allow the operator to change the position the
position of the holder rotate by delaying the stop of the holder a set
amount of time.
Using the procedure described in
Use the up and down arrows to scroll down to the ROTATE DELAY
option.
ROTATE DELAY
The below screen will appear
HORIZONTAL
VERTICAL
For both the horizontal and vertical, 0 is the default setting. The Rotate
Delay for both settings value can be adjusted on a range of 0 to +100.
GBC eWire
GP
6.1.3, enter Service mode.
*
*
GP
6.1.3, enter Service mode.
*
*
When the desired value has been selected, press ENTER to return to
the service menu.
Select EXIT and press ENTER to return to the top level menu.
GP 6.3.18
DESKEW ADJUST
The DESKEW ADJUST setting will allow the operator to change the
amount the aligner carriage corrects for skewed sheets entering the
eWire.
Using the procedure described in
Use the up and down arrows to scroll down to the DESKEW ADJUST
DESKEW ADJUST
The below screen will appear
DESKEW ADJUST
0
0 is the default setting. The Deskew Adjust value can be adjusted on a
range of -20 to +20. When the desired value has been selected, press
ENTER to return to the service menu.
Select EXIT and press ENTER to return to the top level menu
GP 6.3.19
VOLTAGE
The Voltage option in the service menu will display information on the
voltage in the eWire.
Using the procedure described in
Use the up and down arrows to scroll down to the Voltage option.
24: Status of the 24v coming supplied from the power supply
24i: Status of the 24v supplied to eWire through the interlocks
5: Status of the 5v power supplied to the eWire
3.3: Status of the 3.3v power supplied to the eWire
01/26/2018
6-19