REP 2.18 Solenoid Replacement, Diverter Solenoid (L1)

PARTS LIST ON PL 5.3
Use this procedure to remove and install the Diverter Solenoid Assembly.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 1.1
Top Cover Replacement
4. Remove the M4 Screws (5) to remove the Lower Bypass Rear Cover.
Repairs/Adjustments
to remove the Top Cover.
5. Remove M4 Screws (2) connecting the Solenoid linkage to the
Diverter shaft.
6. Disconnect the solenoid wires at the header