Rep 6.5 Closer Jaw Insert Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

Installation Procedure
1. Install the Gear onto the Motor shaft and secure it using the set
screw.
2. Position the Motor into the Closer Module and secure it using the M5
Screws (4)
3. Check the alignment of the Pinion Gear on the Motor to the larger
Drive Gear on the Closer. If necessary, adjust the Pinion Gear
position to ensure proper alignment.
4. Connect the Motor Cable.
5. Connect the Power Cord.
6. Power ON the eWire.
Repairs/Adjustments

REP 6.5 Closer Jaw Insert Replacement

PARTS LIST ON PL 5.19
Use this procedure to remove and install the Closer Jaw Insert. Note that
the same procedure is used to replace the Upper and Lower Closer Jaws.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 6.1
Closer Module Replacement
4. Using an Allen wrench, remove the M3 SHCS (2) to release the Jaw
Insert.
5. Repeat the process for the opposite Jaw Insert.
01/26/2018
4-134
to remove the Closer.
GBC eWire