Rep 3.15.4 Element Transfer Rack Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

5. Disconnect the Sensor Cable. Secure the cable end with tape so it
does not fall back through the opening.
6. Repeat the procedure for the opposing sensor if necessary.
Installation Procedure
1. Connect the Sensor Cable to the new Sensor.
2. Align the new Sensor with the appropriate mounting bracket using the
tab for alignment.
3. Secure the new Sensor using the M3 screw.
4. Repeat the procedure for the opposing sensor if necessary.
5. Replace the Element Transfer Top Cover.
6. RConnect the Power Cord.
7. Power ON the eWire.
GBC eWire

REP 3.15.4 Element Transfer Rack Replacement

PARTS LIST ON PL 5.13
Use this procedure to replace the rack component on the Element
Transfer module. There are a total of 4 Rack parts on the Element
Transfer Module.
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Remove the Expanding T top cover by removing the M3 Screws (4).
4. Remove the M3 Screws (2) securing the Rack to the frame.
5. Carefully remove the Rack by sliding it out of the module.
6. Repeat the procedure for the remaining Rack parts if necessary.
01/26/2018