Rep 2.10 Stepper And Mount Assembly Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

Installation Procedure
1. Place the new Belt into position around the Driver and Idler Pulleys.
2. Adjust the Belt tension. The belt should be taut but still be able to flex
approximately 1" when you press on it.
3. Replace the M2 Stepper Motor cable.
4. Do REP 1.1
Top Cover Replacement
5. Connect the Power Cord.
6. Power ON the eWire.
Repairs/Adjustments
to replace the Top Cover.

REP 2.10 Stepper and Mount Assembly Replacement

PARTS LIST ON PL 5.3
Use this procedure to remove and install the Bypass 1 (M1) and Bypass 2
(M2) stepper motors.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 1.1
Top Cover Replacement
4. Locate the affected Motor.
5. Disconnect the Motor Connector from the corresponding Motor Driver.
6. Remove tension from the Belt by loosening the Belt Tensioner.
01/26/2018
4-26
to remove the Top Cover.