Rep 1.10 Lcd Membrane Switch Panel Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

REP 1.10 LCD Membrane Switch Panel Replacement

PARTS LIST ON PL 5.1
Use this procedure to remove and install the LCD Membrane Switch
Panel.
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire
2. Disconnect the Power Cord.
3. Raise the Upper Transport.
4. Disconnect the LCD Membrane Switch Connector from the LCD
Display.
5. Remove the M3 Screw that secures the ground strap.
6. Using a straight edge, peel off the old LCD Membrane. Carefully
remove any adhesive residue from the panel.
GBC eWire
Installation Procedure
1. Insert the LCD cables through the slot on the panel surface
2. Install the new Membrane to the panel surface of the LCD Panel
using the adhesive. Carefully align the new Membrane to the LCD
display opening. You may be able to use the outline of the old LCD
Membrane as a guide.
3. Connect the LCD Membrane Switch Connector to the LCD Display.
4. Secure the ground strap by tightening the M3 mounting Screw.
5. Connect the Power Cord.
6. Power ON the eWire
01/26/2018