Rep 9.9 Stacker Paper Detect Sensor S44 Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

REP 9.9 Stacker Paper Detect Sensor S44 Replacement

PARTS LIST ON PL 5.26
Use this procedure to remove and install the Stacker Paper Detect
Sensor, S44.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Turn off Power to the eWire.
2. Disconnect the Power Cord.
3. Do REP 4.1
Vacuum Stacker Module Replacement
Vacuum Stacker.
4. Disconnect the Vacuum Fan Cables.
GBC eWire
5. Remove the M4 Screws (4) securing the Vacuum Fan and remove
the old fan.
to remove the
Installation Procedure
1. Reverse the steps in the Removal Procedure
2. Connect the Power Cord.
3. Turn on power to the eWire.