Gp 6.2 User Interface Procedures; Gp 6.2.1 Alignment Setting Adjustment Procedure; Gp 6.2.2 Closing Setting Adjustment Procedure - GBC eWire Service Manual

Table of Contents

Advertisement

GP 6.2
User Interface Procedures
The following section describes the options contained in the eWire User
Interface. The user interface can be accessed by pressing the up or down
arrows on the LCD panel.
GP 6.2.1
Alignment Setting Adjustment Procedure
Do the following to change the Alignment. Changing the alignment setting
will shift the nominal centerline of the sheets toward the front or the rear
of the eWire.
From the top level screen, press either the up arrow button or the
down arrow button.
READY
TO BIND
This displays the SETTINGS - INFORMATION screen
SETTINGS
INFORMATION
Select SETTINGS to enter the setting select menu.
Select ALIGNMENT to enter the alignment adjustment menu.
Press the up arrow or down arrow to change the alignment setting to
the desired value (range -2.0 mm to +2.0 mm). Record the initial
value so you have a reference point to base future adjustments on.
ALIGNMENT OFFSET
0.0 mm
Press the ENTER button when the desired value is displayed for the
Alignment. This will return you to the SETTINGS menu.
Select EXIT and press ENTER to return to the top level menu.
GBC eWire
GP 6.2.2
Closing Setting Adjustment Procedure
Do the following to select the desired closer travel. A higher number
indicates increased close/crimp of element. A lower number will cause the
twin loop element to be crimped less.
Note: Changing the Closing Setting effects only the size that is currently
installed. For example, if the A size spool is currently loaded, changing
the Closing value will not have any impact on the settings for other sizes.
Note: It is recommended to increment Closing Settings by only one value
at a time. Adjusting in larger increments may cause over-adjustment.
From the top level screen, press either the up arrow button or the
down arrow button.
READY
TO BIND
This displays the SETTINGS - INFORMATION screen
SETTINGS
INFORMATION
Select SETTINGS to enter the setting select menu.
Select CLOSING to enter the closing depth adjustment menu.
Press the up arrow or down arrow to change the closing setting to the
desired value (range -5 to +5)
CLOSING
1
Press the ENTER button when the desired value is displayed for the
Closing. This will return you to the SETTINGS menu.
Select EXIT and press ENTER to return to the top level menu.