RAP 4.15
J364- M9 ELEMENT BACKUP STEPS TIMEOUT
J364 is triggered when it takes longer than specified time for M9 Element
sprocket motor to back up the element.
1. Ensure that the element is not tangled on the sprocket of the feed
section.
The Element is not tangled on the sprocket
Yes- Go to Step 2
No- Remove the damaged element and reinstall the spool.
2. Check if the element spool is loaded properly.
Element spool is loaded properly
Yes- Go to Step 3
No- Remove the element spool and reinsert it properly
3. Manually rotate the Element sprocket and ensure smooth operation.
Element tip does not catch corners when moved using the
sprocket
Yes- Go to Step 4
No- If the edge of an element catches a corner, trim the edge.
Resume normal operation
4. Ensure there are no obstructions or residual fragment of the element
on the belt.
The Element belt is free of obstructions
Yes- Go to Step 5
No- Remove the obstructions and ensure smooth travel of the belt.
5. Manually rotate the Element belt and ensure smooth operation
The Element belt moves smoothly without any binding
Yes- Go to Step 6.
No- Go to Step 7
6. Do GP 6.5 to check M9 Element feed sprocket motor
This clears the fault
Yes- Return to normal operation;
No- Go to step 5
GBC eWire
7. Inspect the Element sprocket nose sub-assembly for any damage.
Element sprocket nose sub-assembly is damaged.
Yes- Replace the Sprocket Nose sub-assembly (REP 3.13);
No- Go to Step 6
8. Do GP 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the
firmware for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 9
9. Do REP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 10
01-26-2018
2-41