Rep 3.15.2 Pushover Home Sensor Replacement S24 - GBC eWire Service Manual

Table of Contents

Advertisement

Installation Procedure
1. Place the new Sensor onto the Encoder Sensor Bracket and align it
using the tab. Secure the Sensor using an M3 Screw.
2. Install the Encoder Sensor Bracket.
3. Connect the Power Cord.
4. Power ON the eWire.

REP 3.15.2 Pushover Home Sensor Replacement S24

PARTS LIST ON PL 5.12
GBC eWire
Use this procedure to remove and install the Pushover Home Sensor.
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 3.15
Element Transfer Module Replacement
Element Transfer Module.
4. Disconnect the Sensor Cable from the Pushover Home Sensor.
5. Remove the Pushover Home Sensor by removing the M3 Screw.
Slide the old Sensor up and out of the machine.
Installation Procedure
01/26/2018
4-83
WARNING
to remove the
Repairs/Adjustments

Advertisement