REP 3.15.1 Element Pushover Encoder Sensor Replacement S31
PARTS LIST ON PL 5.12
Use this procedure to remove and install the Pushover Encoder Sensor
on the Element Transfer Module.
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
5. Remove the old sensor by removing the M3 Screw.
2. Disconnect the Power Cord.
3. Disconnect the Sensor Cable from the Pushover Encoder Sensor.
4. Remove the Encoder Sensor Bracket by removing the M3 Screws (2).
GBC eWire
Repairs/Adjustments
01/26/2018