RAP 4.19
J368- PUSHOVER FWD ENCODER TIMEOUT
J368 is triggered if it takes longer than specified time to count the encoder
steps needed for the Pushover to go in the forward direction.
1. Do GP 6.4 to check S31 Pushover encoder sensor
This clears the fault
Yes- Return to normal operation;
No- Go to Step 2
2. Do GP 6.5 to check M12 Element pushover motor
This clears the fault
Yes- Return to normal operation;
No- Go to Step 3
3. Replace the Pushover Motor Assembly (PL 5.13)
This clears the fault
Yes- Return to normal operation;
No- Go to Step 4
4. Do 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the firmware
for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 5
GBC eWire
5. Do REP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level
01-26-2018
2-44
RAPS