Rep 6.6 Closer Spring Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

Installation Procedure
1. Position the Jaw Insert in place and secure it using the M3 SHCS (2)
2. Repeat the process for the opposite Jaw Insert.
3. Do REP 6.1
Closer Module Replacement
4. Connect the Power Cord.
5. Power ON the eWire.
GBC eWire
to install the Closer Module.
01/26/2018

REP 6.6 Closer Spring Replacement

PARTS LIST ON PL 5.19
Use this procedure to remove and install the Closer Extension Springs.
Note that the same procedure can be used for springs on each side of the
Closer.
Removal Procedure
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 6.1
Closer Module Replacement
4. Remove the Extension Spring by disconnecting each end. The top of
the spring can be accessed from the window in the upper plate.
5. Repeat the process for the opposite spring.
4-135
WARNING
to remove the Closer.