4 WIRE JAM CODES

RAP 4.1
J320- S20 SPOOL ELEMENT SLACK TIMEOUT
S20 Element Slack time out is the maximum time to wait for
S20_Element_Slack sensor to detect a wire.
1. Check if the rewind paper from the spool has been
cut/damaged/slipped.
Rewind paper appears to be damaged/cut
Yes- Clear the Rewind Spool and reinsert the rewind paper;
No- Go to Step 2
2. Reinstall the Supply Spool.
Replacing the spool with a new one fixes the problem
Yes- Reinstall the correct size spool and continue operation;
No- Go to Step 3
3. Perform GP 6.13 to clean the base of the Element feeder. Ensure that
the slack detect mechanism moves freely without any obstruction.
This clears the fault
Yes- Return to normal operation;
No- Go to step 4
4. Do GP 6.4 to check S20 Element slack sensor.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 5
5. Do GP 6.5 to check M8 Spool rewind motor.
This clears the fault
Yes- Return to normal operation;
No- Go to step 6
6. Check the Rewind Belt Pulley (Green Belt)
Pulley is intact and has proper tension
Yes- Go to Step 7;
No- Do REP 3.9 to replace the Pulley Assembly
GBC eWire
7. Perform ADJ 1.2 Element Slack Detection Adjust.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 8
8. Check the condition of Element slack detect sub-assembly (PL 5.10)
Element slack detect sub-assembly is in good condition
Yes- Go to Step 9;
No- Replace Element slack detect sub-assembly
9. Do GP 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the
firmware for eWire.
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level
01-26-2018
2-29