Rep 3.15.11 Expanding T Motor Counterbalance Spring Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

Installation Procedure
1. Secure the new spring to the Expanding T by placing the loops on
each end of the spring onto the appropriate hooks on the Element
Transfer and Expanding T.
2. Repeat the process for the remaining springs.
3. Replace the Expanding T Top Cover.
4. Connect the Power Cord.
5. Power ON the eWire.
GBC eWire

REP 3.15.11 Expanding T Motor Counterbalance Spring Replacement

PARTS LIST ON PL 5.13
Use this procedure to remove and install the Expanding T Motor
Counterbalance Spring.
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Open the Element Feeder door and slide out the Element Feeder
drawer.
4. Remove the old spring by pulling the end of the spring off the
mounting hole. Repeat for the other end of the spring.
01/26/2018
4-93
WARNING
Repairs/Adjustments

Advertisement

Table of Contents
loading

Table of Contents