Adj 1.14 Element Xfer Position Adjustment - GBC eWire Service Manual

Table of Contents

Advertisement

ADJ 1.14 Element Xfer Position Adjustment

The element transfer position controls the position of the wire while it is
being transferred from the Element Feeder to the Holder. Changing this
value will adjust the amount of travel for the element feed belt prior to
transferring the wire.
1) If the element transfer position is off, the most likely result is difficulty
with successfully picking up the wire and placing it onto the Holder.
2) Check for consistent issues with wire falling off the Holder. The wire
could be completely off the Holder and loose inside the machine. It
could also be poorly held on the Holder and partially fall off during
operation.
3) If these issues are seen, changing the Element Xfer Position may
help.
4) Always note the initial setting so you can return to this value if
needed.
Adjustment Procedure
1) Access the Service Menu and select ELEMENT XFER POS
2) Increment the value +5 and -5 and run a test in each configuration.
Test the element transfer by selecting FUNCTION TEST 
ELEMENT CYCLE  FEED ELEMENT. Repeated tests might be
necessary to determine if the problem is resolved.
3) If improvement is seen by increasing or decreasing this value,
continue to adjust the setting until the problem is fully resolved.
4) Run a number of books to verify the adjustment made has solved the
problem.
5) If no improvement is seen by changing the value, reset to the original
setting and return to the RAP that directed you here.
Repairs/Adjustments
01/26/2018
4-204
GBC eWire

Advertisement