Rep 4.5 Motor Replacement, Vacuum Stacker Drive (M5) - GBC eWire Service Manual

Table of Contents

Advertisement

REP 4.5 Motor Replacement, Vacuum Stacker Drive (M5)

PARTS LIST ON PL 5.14
Use this procedure to remove and install the Vacuum Stacker stepper
motor.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 4.1
Vacuum Stacker Module Replacement
Vacuum Stacker.
4. Disconnect the motor cables from the header.
5. Remove the motor top cover by loosening the M3 screws (3).
6. Use an Allen wrench to loosen the set screw securing the belt drive
pulley.
Repairs/Adjustments
7. Remove the M4 Screws securing the motor and remove the motor
from the Vacuum Stacker.
to remove the
Installation Procedure
1. Reverse the steps from the Removal Procedure. Ensure that the
2. Do REP 4.1
3. Connect the Power Cord
4. Turn on the eWire.
01/26/2018
4-106
drive belt has proper tension after motor installation.
Vacuum Stacker Module Replacement
Vacuum Stacker.
to install the
GBC eWire