7. Do GP 6.5 to check M15 Holder linear drive motor
This clears the fault
Yes- Return to normal operation;
No- Go to step 8
8. Inspect the springs for the Holder gates (PL 5.21).
Holder gates springs are present and not damaged
Yes- Go to Step 9;
No- Replace the missing/damaged spring
9. Do 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the firmware
for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 10
10. Do REP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Resume operation;
No- Escalate to second level
GBC eWire
RAP 5.3
J372- S39 DETECT AT REV GATE TIMEOUT
J372 is triggered if it takes longer than specified time for the Holder to
reach S39 Holder at Reverse Gate sensor
1.
Do GP 6.4 to check S39 Holder at Reverse gate sensor
This clears the fault
Yes- Return to normal operation;
No- Go to Step 2
2. Check the Condition of the Holder linear drive belt- Front and Rear
(PL 5.21)
The timing belt is in good condition. There are no missing teeth
and the belt is not frayed
Yes- Go to Step 3;
No- Replace the damaged timing belt (REP 8.11, 8.12) and resume
operation
3. Check the tension of the Holder linear drive belt tension- Front and
Rear (ADJ 1.6)
The tension of the timing belts is good
Yes- Go to Step 4;
No- Do to ADJ 1.6 to set the belt tension and resume operation
4. Visually check if the rollers of the Holder are centered in the cam
tracks.
The rollers are centered in the cam tracks
Yes- Go to Step 5;
No- Loosen the cam track assembly and bring the roller inside the
cam track. Resume operation
01-26-2018