Power Faults; Rap 2.1 No Ac Power - GBC eWire Service Manual

Table of Contents

Advertisement

2 POWER FAULTS

RAP 2.1
No AC Power
Use this RAP when there is no AC power to the eWire. The Operator
Panel does not illuminate and the eWire does not operate. Check if the
LEDs on the Main Control Board A and Main Control Board B are lit.
1. Ensure the Power is ON for the print engine and eWire. The Power
switch is located at the rear side of the machine.
Main Power Switch is in the On (I) position
Y
N
Place the Main Power Switch in the On (I) position.
2. Check that the Power Cord is attached to the AC Filter on the rear of
the machine.
Power Cord is attached to AC Filter.
Y
N
Attach the Power Cord.
3. Check that the Power Cord is properly plugged into the wall.
Power Cord is plugged into the wall.
Y
N
Plug in the Power Cord.
4. Disconnect the Power Cord from the power source and check the
power source voltage - 110 VAC (60 Hz) or 240 VAC (50 Hz) - at the
power receptacle.
AC power is present at correct value at the recepticle.
Y
N
If there is no power at the outlet, ask the customer to call an
electrician to restore the AC power.
5. Reconnect the power cord to the eWire.
6. Do REP 1.5 to remove the Rear Cover.
7. Check that Ground Wire 7715525 (See Section 7, page 7-3) is
connected to the ground and to the AC Filter.
Ground Wire is connected.
Y
N
Connect Ground Wire.
Go to step 8.
GBC eWire
8.
01-26-2018
2-12
RAPS