Rap 4.10 J350- Spool Near Empty - GBC eWire Service Manual

Table of Contents

Advertisement

7. Do GP 6.5 to check M10 Element feed belt motor
This clears the fault
Yes- Return to normal operation;
No- Go to step 8
8. Do GP 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the
firmware for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 9
9. Replace the Element feed belt (REP 3.6)
This clears the fault
Yes- Return to normal operation;
No- Go to Step 10
10. Do REP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level
GBC eWire
RAP 4.10
J350- SPOOL NEAR EMPTY
J350 is displayed when the Element spool does not have sufficient
elements to make books. Follow this procedure if the machine
erroneously displays this message with an element spool with at least one
full row of elements
1. Check if the element spool is loaded properly, and if it contains at
least one row of elements. Try loading a fresh spool and repeating
the process.
Element spool is loaded properly, it contains at least one row of
elements. The problem exists with more than one spool
Yes- Go to Step 2;
No- Refer to GP 6.7 to properly install the spool.
2. Do GP 6.4 to check S50 Spool Near Empty sensor
This clears the fault
Yes- Return to normal operation;
No- Go to step 3
3. Inspect spool spindle sub-assembly, replace if necessary
Spool spindle sub-assembly is in good condition
Yes- Go to Step 4;
No- Replace Spool spindle sub-assembly.
4. Do GP 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the
firmware for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 5
5. Do REP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level
01-26-2018
2-37
RAPS

Advertisement

Table of Contents
loading

Table of Contents