1. Place the new Sensor onto the mounting bracket and align it using
the tab. Secure the Sensor using an M3 Screw.
2. Connect the Sensor Cable to the new Sensor.
3. Do REP 3.15
Element Transfer Module Replacement
Element Transfer Module.
4. Connect the Power Cord.
5. Power ON the eWire.
Repairs/Adjustments
REP 3.15.3 Expanding T Home and Out Sensor Replacement S32 &

S33

PARTS LIST ON PL 5.12
to install the
Use this procedure to remove and install the Expanding T Home Sensor
S32 and the Expanding T Out Sensor S33. S32 and S33 can be replaced
using the same general procedure.
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Remove the Expanding T top cover by removing the M3 Screws (4).
4. Remove the Sensor by removing the M3 Screw. Carefully pull the
sensor up through the opening in the module.