Installation Procedure
1. Lift the Back Cover assembly and align the tabs with the slots in the
machine frame.
2. Carefully lower the cover tabs into the appropriate slots. Lean the
cover forward until it is flush with the back of the frame.
3. Tighten the M4 Screws (2) to secure the Back Cover.
4. Connect the Power Cord.
5. Switch power ON to eWire.
Repairs/Adjustments

REP 1.6 Side Cover Replacement

PARTS LIST ON PL 5.28
Use this procedure to remove and install the Side Covers (2).
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire
2. Disconnect the Power Cord.
3. Hold the Side Cover in place so it doesn't fall as you remove the M4
Screws (2) from the Side Cover.
4. Carefully tilt the Side Cover back and then lift the Side Cover out of
the tabs in the machine frame.
Installation Procedure
1. Lift the Side Cover assembly and align the tabs with the slots in the
machine frame.
2. Carefully lower the cover tabs into the appropriate slots. Lean the
cover forward until it is flush with the side of the frame.
3. Tighten the M4 Screws (2) to secure the Side Cover.
4. Connect the Power Cord.
5. Switch power ON to eWire.